Product index
41040
|
Product number
TR2102
|
Product name
TOWER COATING GREY
|
Product group
1
|
Summary code
HS
|
Product description
Termarust® TR2102 High Ratio Co-Polymerized Calcium Sulfonate Tower Coating is a pigmented Bi- Functional coating System, designed and engineered exclusively for encapsulation (overcoat) of existing aged leaded paints, vinyls, coal tar epoxy, polyurethanes, epoxy mastics, organic or inorganic zinc, galvanizing, metallizing, acrylics, core 10 steel and tightly adhered contaminant free rust, or re-coating of new or prepared structural steel transmission towers and aging utility sub-stations. Ideal for use with Low to High Pressure Water Cleaning. ie: 5000 PSI at 5 Gallons per minute.
|
Uses
Termarust TR 2102 Self-Priming Topcoat allows tremendous flexibility in surface profile and preparation. It is ideal for the reclamation and long term protection of utility towers and sub-station steel structures and flexible industrial infrastructure
|
Advantages
Termarust® TR2102 Tower Coating enhances the following characteristics:
Advanced Technology
Applicator Friendly
High Performance
Surface Tolerant
Single Component
Non Hazardous
Single Coat
Low VOC
High Solids
Non-conductive Insulation Value passed 100 Kilavolts DC
Superior Anti-Corrosive Protection
Field proven performance
|
Chemistry + solvents
High Ratio Co - Polymerized Calcium Sulfonate
|
System solvent
Termarust Thinner TRT01
|
Color
All colors available on request
|
Gloss
Flat
|
Mix ratio
NA
|
Viscosity
15000-25000 CPS ASTM D2196 RVT #6 AT 10 RPM
|
Solids by weight
87% ± 2% (depending on color) ASTM D2369
|
Solids by volume
86.7% ± 2% (depending on color) ASTM D2697
|
Density
NA
|
Volatile Organic Compounds (VOC)
100-120 grams per litre
.83-..99 lb. /U.S. Gallon.
|
Sag resistance
NA
|
Dry Film Thickness (DFT)
150 - 250 microns - 6 - 10 mils DFT
|
Spread rate
34 sq. m. per litre @ 25 microns DFT
1389 sq. ft. per U.S. Gal. @ 1 mil DFT
|
Dry time
12 to 24 hours depending on film thickness
Note: Does not get brittle like conventional paints
|
|
Working pot life
NA
|
Performance data
NA
|
Chemical resistance
NA
|
Surface preparation
All grease, oil, grime, and other contaminants must be removed from the surface using Termarust Formula 1X cleaner, commercial detergent or other suitable cleaning method (SSPC-SP1). Hand tool cleaning (SSPC-SP2), power tool cleaning (SSPC-SP3), or Low to High Pressure Water Cleaning (SSPC-SP12-WJ4), is sufficient preparation to produce excellent results, The prepared surface must be analyzed for Chloride Nitrate and Sulfate content. Upper limit is per SSPC SP12-NV2. when using water. See painting spec for allowable levels when abrasive blasting.
|
Application
The Termarust TR 2102 Tower Coating should not be applied at temperatures below 2°+C or 35.5°+F with a steel temperature not less then 2°+C or 35.5°+F. There must be a 2° C or 5° F spread between temperature and dew point. To apply the coating the relative humidity should be no greater than 99% and the steel should be free of surface moisture.
|
Application equipment
NA
|
Compatible systems
TR 2100 High Ratio Co-Polymerized Calcium Sulfonate Primer Topcoat
|
Thinning
Brush/Roller: Up to 10% with TRT01
Conventional Spray: 10% with TRT01
Airless Spray: No thinning required
|
Clean up
Use TRT01
|
LC50 TROUT 96 HOURS
41,007 ppm
|
WEIGHT PER GALLON
1.23 kg/litre ± .25%
10.79 lbs/US Gal. ± .25%
|
OTHER PROPERTIES
Resistance to fresh water immersion: excellent
Resistance to seawater immersion: fair
Resistance to seawater splash zones: excellent
Resistance to aliphatic solvents: fair
Resistance to aromatic solvents: poor
Flexibility: good-excellent
Ultimate film hardness (ASTM D3363): 4B
|
Shelf life
12 months minimum in original unopened container when stored in a protected area where the temperature is between 5°C and 30°C (41°F - 86°F).
|
Safety precautions & regulatory data
Treat as flammable liquid - Flashpoint 42°C (108°F). Keep away from heat, open flame and sparks. Avoid contact with skin and eyes. Avoid prolonged breathing of vapor. Read label instructions carefully and refer to Material Safety Data Sheet supplied. This product is for industrial use only and is not intended for use in or around a household or dwelling.
*All films pigmented, data is formulation dependent.
|
Notes
Note: After 12 months verify the coating to see if a skin has formed. If a skin is present remove skin and mix the material. Before an open container is closed a thin layer of TRT 01 should be poured on top. This will retard any skinning.
|
|