Products
Technical data


Product index
41050

Product number
TR2200LV 

Product name
PENETRANT/SEALER  

Product group
1  

Summary code
HS  

Product description
Termarust TR2200LV HR CSA (High Ratio Co-Polymerized Calcium Sulfonate) is a high performance, Low VOC, environmentally friendly, proprietary penetrant sealer formulated specifically to remain active. Its unique properties allow it to neutralize acid, displace moisture, scavenge oxygen, thoroughly wet surfaces and stop corrosion, pack rusting, and rust staining (bleeding) on steel structures. The unique chemistry addresses the physical and chemical components of the crevice corrosion and pack rust.  

Uses
For application to joints, crevices, back to back angles, corrosion frozen bearings and tubing on steel structures such as bridges, towers, cranes, conveyor systems, cable suspension systems and vehicle frames where coating is impossible.  

Advantages
The Termarust TR2200LV HR CSA (High Ratio Co-Polymerized Calcium Sulfonate)Penetrant/Sealer's active chemistry is like chemotherapy for steel structures. The TR2200LV HR CSA Penetrant/Sealer chemically attacks the corrosion from the inside, neutrlizing the corrosion causing chemistries so they can no longer feul the fires of corrosion.  

Chemistry + solvents
HR CSA (High Ratio Co-Polymerized Calcium Sulfonate) ( Minimum 15% active sulfonate, a total base number of 15 to 170, must maintain a 10 to 1 ratio Active Sulfonate to Total Base Number)  

System solvent
Termarust thinner TRT 01  

Color
Clear amber solution  

Gloss
Low Gloss  

Mix ratio
NA 

Viscosity
24-30 seconds #4 Ford 

Solids by weight
92% ± 2%

 

Solids by volume
83.8% ± 2%

 

Density
NA 

Volatile Organic Compounds (VOC)
128-135 grams per litre
.9-1.2 lbs/US Gallon
 

Sag resistance
NA 

Dry Film Thickness (DFT)
Variable 

Spread rate
35.6 sq. m. per litre @ 25 microns DFT
1344.2 sq. ft. per U.S. Gal. @ 1 mil DFT
 

Dry time
When used as a penetrant only allow 24 hours for maximum penetration. Termarust TR2200LV High Ratio Co-Polymerized Calcium Sulfonate Penetrant/Sealer may be topcoated wet on wet when an extra 10 mils DFT of Termarust TR2100 HR CSA Primer/Topcoat is applied to the pack rusted joints, crevices, or back to back angles during the cutting in process.

 

Working pot life
NA 

Performance data
NA 

Chemical resistance
NA 

Surface preparation
Spot repairs of failed joints
Remove excessive dirt and contaminants by using appropriate cleaners and also a soluble salt remover like Termaclean 7101 or Chlor-rid. Open joints with a sharp object to allow the Termarust TR2200LV HR CSA (High Ratio Co-Polymerized Calcium Sulfonate) Penetrant/Sealer to penetrate thoroughly.

Waterjetting joints
Wash joints using 5000 PSI water at a maximum 4 inch stand off. Joints should be blown out with a minimum 100 PSI clean dry high-pressure air to insure water has been removed. When used without the Termarust TR2100 HR CSA (High Ratio Co-Polymerized Calcium Sulfonate) Primer/Topcoat, two applications of the Termarust TR2200LV HR CSA (High Ratio Co-Polymerized Calcium Sulfonate) Penetrant/Sealer are recommended for maximum performance. In this case allow at least 12 hours between application of the second coat of the TR2200LV HR CSA Penetrant/Sealer.

 

Application
Thoroughly wet out all joints, crevices, cables, back to back angles, tube interiors and areas to be protected with Termarust TR2200LV HR CSA (High Ratio Co-Polymerized Calcium Sulfonate) Penetrant/Sealer by spray or brush.
Excessive Termarust TR2200LV HR CSA (High Ratio Co-Polymerized Calcium Sulfonate) Penetrant/Sealer allowed to remain on other surfaces will inhibit the dry of the Termarust TR2100 HR CSA (High Ratio Co-Polymerized Calcium Sulfonate) Primer/Topcoat and should be brushed out.
 

Application equipment
Any Equipment that can spray via pressure or facilitate the application of the TR2200LV HR CSA penetrant/ Sealer into the crevice corrode joints and connection to facilitate the maxium amount of penetration thus asurring the best end result.  

Compatible systems
Termarust TR2100 HR CSA (High Ratio Co-Polymerized Calcium Sulfonate) Primer/Topcoat (Remove excess Termarust TR2200LV High Ratio Co-Polymerized Calcium Sulfonate Penetrant/Sealer before applying topcoat) 

Thinning
Spray: No thinning required 

Clean up
Termarust Thinner TRT 01 

LC50 TROUT 96 HOURS 
41,007 ppm (does not adversely effect marine life) 

SALT FOG 
500 HRS (Coating applied at 1-2 mils dry film over SSPC-SP5 cold rolled steel panels).Must pass with no rust or creepage at the scribe. 

WEIGHT PER GALLON 
9.98lbs ± .25

 

Shelf life
12 months in original unopened container when stored in a protected area where the temperature is between 5°C and 30°C (41°F - 86°F). After 12 months material should be mixed and inspected before use. 

Safety precautions & regulatory data
Treat as flammable liquid - Flashpoint 42°C (108°F). Keep away from heat, open flame and sparks. Avoid contact with skin and eyes. Avoid prolonged breathing of vapor. Read label instructions carefully and refer to Material Safety Data Sheet supplied. This product is for industrial use only and is not intended for use in or around a household or dwelling. 

Notes
The technical data given herein has been compiled for your help and guidance and is based upon our experience and knowledge. It is subject to modification from time to time in the light of experience and our policy of continuous product development. Persons using this product must first satisfy themselves as to its suitability for the intended purpose. Please contact your representative for complete recommendations. A complete Termarust TR2200LV High Ratio Co-Polymerized Calcium Sulfonate Penetrant/Sealer application specification is available upon request. 



Last change: Version: 26.6:.2010   


                               
THE BEST CORROSION CONTROL PERFORMANCE GUARANTEED


 
Copyright 2002-2010 Termarust Technologies. All rights reserved.