Tank at Atlanta Airport
Type of Project:
Maintenance painting of tank.
Project Description:
Power wash clean, spot prime and overcoat the tank, pipe fittings and the ends of connecting pipes with Termarust.
Reason project was undertaken:
Existing coating on the structure was failing and crevice corrosion and pack rust was developing.
Name and location of facility:
Hartsfield Airport, Atlanta, Georgia. USA
Project start and completion dates:
August 28-29, 2001
Service Environment:
Temperature: +15F to +110F (-9C to 43C), moisture, occasional snow and ice, and some jet aircraft fuel in the air.
Surface Preparation: Methods, degree of cleaning, profile:
Methods, degree of cleaning: 5,000 psi High Pressure water cleaning with zero degree rotating tip and a 4 - 6 inch standoff to a SSPC-SP12 - WJ4-SC2.
Coating application methods, equipment:
Termarust 2200 (RAVCS) Penetrant/Sealer - small squirt bottle, brush and Termarust 2100 (RAVCS) Primer/Topcoat - Airless spray.
Coating system, number of coats, dry film thickness per coat, etc.:
Application of Termarust 2200 (RAVCS) Penetrant/Sealer into joints and connections - followed immediately with (wet on wet) application of Termarust 2100 (RAVCS) Primer/Topcoat.
Caulk coat (stripe coat) all joints and connections with 10 mils DFT Termarust 2100 (RAVCS) Penetrant/Sealer. On all bear metal and tightly adhered, contaminant free rusted surfaces apply spot prime @ 5mils DFT Termarust 2100(RAVCS) Primer/Topcoat, and then overcoat all areas with 5mils DFT Termarust 2100 (RAVCS) Primer/Topcoat.
Safety and Environmental Protection Measures:
A tarp system was used during power washing - to keep debris and overspray of Termarust from a nearby tank.
Unusual Job conditions:
None - the tank was in an open area on airport property.
Evidence of good performance:
After one year of service the coating is performing as expected - with minimum corrosion and delamination of the existing tightly adhered paint.
Why Termarust was used:
The owner wanted a coating with a 5-year warranty and an expected 25-year service life - for this tank.
Owner’s Representative:
Contact: : Lionel White,
Company: Aviation Maintenance Supervisor,Atlanta (Hartsfield) International Airport, Atlanta, Georgia.
Tel: 404-530-6688
Contractor:
Contact: Keith Trammel,
Company: DACA Painting, Inc.
Tel: 770-978-1304
|