Resource center
Case Histories


Ericsson Water Tank





Type of Project:

Reclamation of rusting water tank exterior to insure structural integrity and clean up cosmetics.

Project Description:

High pressure water cleaning of tower with 5,000 PSI water to remove surface contaminants and apply a coating and lettering to the structure.

Reason project was undertaken:

To preserve the tower, stop the corroding joints and connections and cover the graffiti and make it cosmetically acceptable.

Name and location of facility:

Ericson Water Tank, Decarie Expressway, Montreal, Quebec.

Project start and completion dates:

September to November 2001.

Service Environment:

Urban chlorides Sulfonate and nitrate contamination.

Surface Preparation: Methods, degree of cleaning, profile:

5,000 PSI HPWC with a zero degree rotating tip and a 4 inch stand off. Surface preparation was to SSPC-SP12-WJ4-SC2 standard.



Coating application methods, equipment:

Airless spray and brush.

Coating system, number of coats, dry film thickness per coat, etc.:

Termarust TR 2200 RAVCS Penetrant Sealer in all joints and connections Termarust TR 2100 RAVCS Primer Topcoat, at 10 mils DFT on bare metal and rusted surfaces and 5 mils DFT on painted surfaces.

Safety and Environmental Protection Measures:

The contract chose not to use containment and was careful to spray on quiet days.

Unusual Job conditions:

Busy urban area with 10,000 cars parked in the area.



Evidence of good performance:

Two years into the five-year warranty, no rust is leaking from joints and connections.

Why Termarust was used:

Cost was an issue for the owner but they still wanted a good, long-term performance coating and a 5 year warranty against leaking from the pack rusted joints and connections.

Owner’s Representative:
Contact: Guy Garbonneau
Company: Ericsson Communications
Tel: (514) 738-1253

Contractor:
Contact: Norman Lagendyk
Company: Nor-Lag Coatings
Tel: 514-694-7061




 